iLet Contact Detach Infusion Set:
Living with diabetes can be a daily management challenge with a lot of little details that need to be managed. The most essential thing in that routine is your insulin delivery system. Wearing an insulin delivery system may be easier and more manageable with a comfortable, reliable infusion set.
The iLet Bionic Pancreas System is designed to be used with the iLet Contact Detach Infusion Set. It gives users the ability to temporarily disconnect the pump from the infusion site without removing the entire infusion set from the skin.
This may be beneficial for iLet users during certain activities of daily living when temporarily removing the system may be warranted based on their healthcare provider’s recommendations.
Beta Bionics states that the Convatec contact™ detach infusion set is one of the infusion sets that can be used with its iLet system and features a cannula length of 6 mm.
What is the iLet Contact Detach Infusion Set?
iLet Contact Detach Infusion Set is a set for insulin infusion for use with the iLet Bionic Pancreas System. It has an infusion site which remains in place in the body while the pump can be disconnected from the coupling connection.
This design may be beneficial to patients who occasionally need to disconnect the pump from their body but don’t have to use the same infusion set for every pump connection.
The manufacturer says the contact™ detach system enables the temporary disconnection of the pump without the need to replace the entire infusion set.

The system consists of the tube, connector needle, coupling housing, adhesive tape, protective and disconnect parts.
As the infusion set is for insulin use, it must be used according to the instructions of your healthcare professional and the manufacturer.
Why Choose an iLet Contact Detach Infusion Set?
One of the main advantages of the iLet Contact Detach Infusion Set is its disconnectable design.
With a traditional infusion connection, removing the pump may require more planning. The contact detach design allows the pump connection to be separated from the infusion site while the site remains in place.
This can be convenient for some everyday situations.
For example, an iLet user may need to temporarily disconnect from the pump for an activity where the pump should not remain connected. However, whether and for how long you should disconnect should always be based on your iLet training and healthcare provider’s instructions.
Key benefits include:
- Designed for use with the iLet system
- 6 mm cannula option
- Allows temporary pump disconnection
- Infusion site can remain in place during temporary disconnection
- Includes a disconnect cover and protective cap
- Designed for straightforward connection and reconnection
- Available as a sterile, single-use infusion set
Beta Bionics identifies Convatec contact™ detach as one of the infusion sets available for the iLet system.
Understanding the 6 mm Cannula
iLet Contact Detach Infusion Set is a 6 mm cannula.
The small, flexible tube under the skin through which insulin is given from the infusion tubing to the body is called a cannula.
The length of the cannula is also a crucial factor in choosing an infusion set. But users should not select the cannula length for their own liking. Your health care provider, or trained healthcare iLet professional can help you decide what is right for you.
The manufacturer’s literature specifies the contact™ detach option for a 6 mm cannula.
How Does the Contact Detach Feature Work?
The iLet Contact Detach Infusion Set has a coupling connection between the infusion site and tubing.
If the pump must be temporarily disconnected, the needle for the connector can be removed from the coupling housing. The coupling housing is still connected to the skin.
The manufacturer recommends that the connector grips be pressed lightly and the connector needle be pulled straight out. Then a protective cap can be attached to the needle, and a disconnect cover can be fitted over the coupling housing.
In this design, the entire infusion site does not necessarily need to be removed if the pump is temporarily disconnected.
The protective parts are taken off and the connector is inserted into the coupling housing until it clicks into place according to instructions from the manufacturer.
Preparing the iLet Contact Detach Infusion Set
Preparation is important prior to using an iLet Contact Detach Infusion Set.
Review the instructions that are provided with your particular infusion set first. Wash your hands prior to inserting the infusion set, as recommended by the manufacturer.
Your health care professional should determine which area to insert it. The manufacturer also recommends that an infusion site be kept away from an area that is directly adjacent to a previous infusion site.
Skin should be disinfected with disinfectant provided by your health care professional and left to dry before insertion.
Check the package prior to use. Avoid using an infusion set that has an open or damaged package as sterility may be affected.
General Insertion Steps
The exact procedure should always follow the manufacturer’s current instructions for use. In general, the contact™ detach guide describes the following process:
- Wash your hands.
- Select an appropriate insertion site.
- Clean the skin as directed by your healthcare provider.
- Allow the skin to dry.
- Remove the infusion set from its sterile packaging.
- Prepare the connector and tubing.
- Connect the infusion tubing according to the pump manufacturer’s instructions.
- Insert the infusion set as instructed.
- Secure the adhesive against the skin.
- Check the tubing and connection before starting insulin delivery.
The manufacturer’s guide describes inserting the contact™ detach infusion set at a 90-degree angle after preparing the site.
Do not substitute these general steps for the instructions that came with your infusion set.
How to Disconnect the iLet Contact Detach Infusion Set
The iLet Contact Detach Infusion Set has a couple of very convenient features, including the ability to remove the pump for a short time.
The manufacturer’s specification for disconnecting the connector needle from the coupling housing is to press the grips and pull the connector straight out. The guide suggests to put a finger in front of the coupling housing to keep the adhesive from falling out.
After disconnecting, the appropriate protective components should be used as instructed.
The most important thing to note is that an insulin pump can be disconnected, which can impact insulin delivery. Don’t take apart your iLet system just because it looks simple. If your iLet training and healthcare provider advise that the system can be disconnected and for how long, follow their advice.
How to Reconnect
Carefully follow the instructions provided in the iLet Contact Detach Infusion Set to reconnect it.
Users are directed to first remove the disconnect cover from the coupling housing, and then remove the circular protective cap from the connector needle, according to the manufacturer. The tubing should be primed if necessary to follow the directions.
The connector needle is then inserted straight into the connector housing, and the needle clicks.
Once reconnected, look for issues like kinks, air bubbles, disconnection or leakages with the infusion set and tubing.
Since leaking, air bubbles and kinky infusion-set tubing or connections can hinder or prevent insulin delivery, users should inspect these daily, Beta Bionics suggests.
When Should You Change the Infusion Set?
Do not use an iLet Contact Detach Infusion Set for an extended period of time.
Change infusion-set as recommended by the infusion-set manufacturer and as directed by your healthcare provider. Beta Bionics also recommends that the user of an iLet follow the infusion set manufacturer’s recommendations on the frequency of changing an infusion set.
Do not leave an infusion site on the pump for longer than recommended because the disconnect allows for temporary disconnection of the pump.
Scheduled exchange contributes to safe insulin administration and care of the injection site.
Signs You May Need to Check Your Infusion Set
Sometimes the problem is not the iLet device itself but the infusion site, tubing, or connection.
Pay attention to:
- Kinked tubing
- Visible air bubbles
- Loose connections
- Insulin leakage
- A wet or unusual-smelling infusion site
- An infusion site that becomes dislodged
- Unexpectedly high glucose levels
- Alerts or notifications from the iLet system
Beta Bionics advises checking the infusion set, tubing, and connections for leaks, bubbles, and kinks.
If you suspect insulin is not being delivered properly, follow your diabetes care plan and contact your healthcare provider or iLet support as appropriate.
iLet Contact Detach Infusion Set and Everyday Comfort
If you’re wearing an infusion set for long periods, then comfort is important.
Good infusion routine involves more than just insulin delivery. It’s also about determining a location that is compatible with your normal actions, activities, sleep and clothing.
The iLet Contact Detach Infusion Set might appeal to some users since the connection can be disconnect without the need to remove the infusion site immediately.
But some people are more comfortable than others. Your experience may be affected by your skin sensitivity, the adhesive reactions, insertion technique, body movement and site selection.
When irritation or discomfort occurs often, consult with your healthcare provider, don’t try to change insertion technique without doing so.
iLet Contact Detach Infusion Set vs. Other iLet Options
Beta Bionics currently offers two types of infusion set for the iLet system: Convatec “Inset™” detach and Convatec contact™ detach (both 6mm cannula length).
The biggest contrast to all the other users who are considering the iLet Contact Detach Infusion Set is its detachable connection.
This could be helpful for individuals needing or wanting to separate from the pump at times during a specific activity.
The best choice would depend on your own needs and training, comfort, and your healthcare provider’s advice.
Safety Tips for iLet Users
Safety is always the most important, and insulin delivery is a serious medical chore.
Never start operating an iLet system or alter your configuration without proper training. Beta Bionics cautions against improper use, which may lead to insulin delivery that is either excessively high or low, causing either hyperglycemia or hypoglycemia.
Have necessary backup diabetes supplies on hand. Beta Bionics suggests that supplies include blood glucose testing supplies, fast acting carbohydrates, ketone testing supplies, insulin, and additional infusion sets should be included as part of an emergency kit.
Also, it is important to follow medical procedure instructions. iLet system and infusion-set parts may have to be removed for procedures including MRI, CT, PET and some other procedures.
Buying iLet Infusion Supplies
When ordering an iLet Contact Detach Infusion Set, ensure you are getting the right product and setup for your iLet system.
Pay attention to the product packaging, length of cannula, amount of product and compatibility before ordering.
Alfa Healthcare Supply Inc. is a supplier of medical and durable medical equipment supplies for customers that require reliable medical supplies. When purchasing an infusion set, customers should also make sure that they have the appropriate prescription or documentation when required.
Refer to the supplier or healthcare professional for product availability or ordering information, or to ask a question about a particular iLet supply.
Why Proper Infusion Set Care Matters
An infusion set might seem like a small part, but it’s a vital part in insulin delivery.
Insulin delivery may be affected by a damaged set, disconnected tubing, kink, leak or displaced cannula. This is why routine inspection is crucial.
Checking your iLet Contact Detach Infusion Set, tubing, connections and insertion site a few moments a day will help you identify any potential issues early.
If something does not feel like it is right or is not looking right, don’t ignore it.
Final Thoughts: iLet Contact Detach Infusion Set
The iLet Contact Detach Infusion Set provides a new level of flexibility for iLet patients, enabling them to temporarily disconnect from the pump without having to remove the infusion site.
It features a cannula that measures 6 mm and a removable coupling making it one of the infusion-set choices for the iLet Bionic Pancreas System.
To ensure proper use, follow the manufacturer’s recommendations for the infusion set; keep the site clean; check tubing and connection often; and follow the diabetes-management plan given by the health care team.
At Alfa Healthcare Supply Inc., our goal is to make it easier for patients and caregivers to find the medical supplies they need. When comparing iLet supplies, it is important to know why and how the iLet Contact Detach Infusion Set is used to help you discuss your needs with your healthcare provider and select supplies that are suitable to your prescribed system.
iLet Contact Detach Infusion Set – Frequently Asked Questions (FAQ)
1. What is an iLet Contact Detach Infusion Set?
The iLet Contact Detach Infusion Set is an infusion set designed to deliver insulin through a small cannula placed under the skin. It is used with compatible insulin pump systems and allows the tubing to be disconnected when needed.
2. What is the purpose of the Contact Detach feature?
The Contact Detach feature allows users to disconnect the infusion tubing from the site while leaving the inserted cannula in place, following the manufacturer’s instructions.
3. Is the iLet Contact Detach Infusion Set compatible with the iLet Bionic Pancreas?
Compatibility depends on the specific infusion set model and connector. Check the product specifications and the iLet system’s instructions before purchasing.
4. Can I disconnect the iLet Contact Detach Infusion Set while showering?
Some infusion sets allow temporary disconnection for activities such as showering. Follow the manufacturer’s instructions for disconnecting, reconnecting, and managing insulin delivery safely.
5. How often should I change the iLet Contact Detach Infusion Set?
Change the infusion set according to the manufacturer’s recommended wear time and your healthcare professional’s guidance. Replace it sooner if you notice leakage, irritation, dislodgment, or delivery problems.
6. Is the iLet Contact Detach Infusion Set comfortable to wear?
Comfort varies from person to person. Proper site selection, correct insertion, and secure attachment can help improve comfort during everyday activities.
7. Can I reuse an iLet Contact Detach Infusion Set?
The infusion set is intended for single use. Do not reuse the set or its insertion components. Follow the manufacturer’s disposal instructions.
8. How do I choose the right iLet Contact Detach Infusion Set?
Check the connector type, cannula specifications, tubing configuration, and compatibility with your insulin delivery system. Ask your diabetes care team or medical supply provider if you are unsure.
9. Where can I buy an iLet Contact Detach Infusion Set?
You can check availability through Alfa Healthcare Supply Inc. at alfahealthcaresupplyinc.com. Confirm the exact model and compatibility before ordering.
10. What should I do if the infusion set leaks or becomes loose?
Follow your insulin pump manufacturer’s troubleshooting instructions and check your blood glucose as directed by your diabetes care plan. Replace the set if needed, and contact your healthcare professional if insulin delivery may have been interrupted or your glucose levels are unexpectedly high.
Medical Disclaimer: This article is for educational purposes only and does not replace professional medical advice, diagnosis, or treatment. The iLet Bionic Pancreas System requires a prescription and appropriate training. Always follow the current manufacturer instructions and your healthcare provider’s recommendations.